Comparison of ultrasound measurement of vena cava inferior diameter and measurement of body composition using bioelectrical impedance for the assessment of fluid status in newborn infants
DOI:
https://doi.org/10.6016/ZdravVestn.3501Keywords:
newborn, organism hydration status, ultrasonographic imaging, vena cava inferior, electric impedanceAbstract
Background: Neonatal medical conditions often disrupt the physiological processes that regulate fluid balance, so assessing fluid status in sick neonates is important for clinical management. In clinical practice we use clinical signs, which, however, on their own, do not provide a reliable assessment of fluid status. We aimed to compare two methods: i) diameters and collapsibility index of vena cava inferior (VCI) measured by ultrasonography and ii) analysis of body composition by bioelectrical impedance (BIA) and to evaluate their relation to changes in body mass.
Methods: In a cohort-prospective clinical trial we included 27 neonates aged 1–7 days with various pathologies. Ultrasound measurements of VCI transversely and longitudinally, measurements of body composition by BIA and measurements of body mass were performed in each subject at least three times with an interval of 24–72 hours. Simultaneous measurements of the same subject were then analysed and evaluated.
Results: The average proportion of total body water (TBW) decreased in the first days after birth, from 80.3% (Day 1) to 73.1% (Day 8) (p = 0.006). The decrease in the average proportion of extracellular water (ECW) in the first days after birth was not statistically significant. The association between ECW and body mass over time was statistically significant (p < 0.001). The association between transversely measured large VCI diameter during inspiration, body mass, and ECW was statistically significant (p = 0.024). No statistically significant association with ECW or body mass was proven for the other ultrasound-measured variables.
Conclusions: By measuring body composition with BIA, we confirmed the reduction of the average proportions of TBW after birth and the association between body mass, ECW, and transversely measured maximal diameter of VCI during inspiration. BIA is an appropriate method for monitoring fluid status in a newborn. Additional research on a larger number of subjects is needed to define the significance of VCI measurements for assessing fluid status.
Downloads
References
1. Jain A. Body fluid composition. Pediatr Rev. 2015;36(4):141-50.
DOI: 10.1542/pir.36-4-141
PMID: 25834218
2. O’Brien F, Walker IA. Fluid homeostasis in the neonate. Paediatr Anaesth. 2014;24(1):49-59.
DOI: 10.1111/pan.12326
PMID: 24299660
3. Tobias A, Ballard BD, Mohiuddin SS. Physiology, Water Balance. Treasure Island (FL): StatPearls Publishing; 2024. [cited 2024 Feb 28].
4. Kim CR, Katheria AC, Mercer JS, Stonestreet BS. Fluid Distribution in the Fetus and Neonate. In: Polin RA, Abman SH, Rowitch DH, Benitz WE, Fox WW, eds. Fetal and Neonatal Physiology. 5th ed. Philadelphia: Elsevier; 2017. pp. 1081-9.
DOI: 10.1016/B978-0-323-35214-7.00112-8
5. Friis-Hansen B. Body water compartments in children: changes during growth and related changes in body composition. Pediatrics. 1961;28(2):169-81.
DOI: 10.1542/peds.28.2.169
PMID: 13702099
6. Nosan Gregor. Tekočinsko in elektrolitsko ravnovesje novorojenčka. In: Paro-Panjan D. , urHemodinamsko, tekočinsko in elektrolitsko ravnovesje pri novorojenčku : [učbenik]. Ljubljana: Klinični oddelek za neonatologijo, Pediatrična klinika, UKC; 2016.
7. Lindower JB. Water balance in the fetus and neonate. Semin Fetal Neonatal Med. 2017;22(2):71-5.
DOI: 10.1016/j.siny.2017.01.002
PMID: 28153467
8. Kieliszczyk J, Baranowski W, Kosiak W. Usefulness of ultrasound examination in the evaluation of a neonate’s body fluid status. J Ultrason. 2016;16(65):125-34.
DOI: 10.15557/JoU.2016.0014
PMID: 27446597
9. Azhibekov T, Soleymani S, Lee BH, Noori S, Seri I. Hemodynamic monitoring of the critically ill neonate: an eye on the future. Semin Fetal Neonatal Med. 2015;20(4):246-54.
DOI: 10.1016/j.siny.2015.03.003
PMID: 25841985
10. Jarosz-Lesz A, Michalik K, Maruniak-Chudek I. Baseline Diameters of Inferior Vena Cava and Abdominal Aorta Measured by Ultrasonography in Healthy Term Neonates During Early Neonatal Adaptation Period. J Ultrasound Med. 2018;37(1):181-9.
DOI: 10.1002/jum.14324
PMID: 28708286
11. Di Nicolò P, Tavazzi G, Nannoni L, Corradi F. Inferior Vena Cava Ultrasonography for Volume Status Evaluation: An Intriguing Promise Never Fulfilled. J Clin Med. 2023;12(6):2217.
DOI: 10.3390/jcm12062217
PMID: 36983218
12. Mugloo MM, Malik S, Akhtar R. Echocardiographic Inferior Vena Cava Measurement As An Alternative to Central Venous Pressure Measurement in Neonates. Indian J Pediatr. 2017;84(10):751-6.
DOI: 10.1007/s12098-017-2382-5
PMID: 28634780
13. Sato Y, Kawataki M, Hirakawa A, Toyoshima K, Kato T, Itani Y, et al. The diameter of the inferior vena cava provides a noninvasive way of calculating central venous pressure in neonates. Indian J Pediatr. 1992;102(6):e241-6.
DOI: 10.1111/apa.12247
PMID: 23586684
14. Lukaski HC, Vega Diaz N, Talluri A, Nescolarde L. Classification of Hydration in Clinical Conditions: Indirect and Direct Approaches Using Bioimpedance. Nutrients. 2019;11(4):809.
DOI: 10.3390/nu11040809
PMID: 30974817
15. Dasgupta I, Keane D, Lindley E, Shaheen I, Tyerman K, Schaefer F, et al. Validating the use of bioimpedance spectroscopy for assessment of fluid status in children. Pediatr Nephrol. 2018;33(9):1601-7.
DOI: 10.1007/s00467-018-3971-x
PMID: 29869117
16. Lingwood BE. Bioelectrical impedance analysis for assessment of fluid status and body composition in neonates—the good, the bad and the unknown. Eur J Clin Nutr. 2013;67(1):S28-33.
DOI: 10.1038/ejcn.2012.162
PMID: 23299869
17. Peterlin J, Blagus R, Kejžar N. Goodness-of-fit tests for functional form of Linear Mixed effects Models. New York: ArXiv; 2019[cited 2021 Aug 25].
18. Demidenko E. Mixed models. 2nd ed. New Yersey: Wiley; 2013.
19. Piccoli A. Bioelectric impedance measurement for fluid status assessment. Contrib Nephrol. 2010;164:143-52.
DOI: 10.1159/000313727
PMID: 20428000
20. Rodríguez G, Ventura P, Samper MP, Moreno L, Sarría A, Pérez-González JM. Changes in body composition during the initial hours of life in breast-fed healthy term newborns. Biol Neonate. 2000;77(1):12-6.
DOI: 10.1159/000014189
PMID: 10658825
21. Schefold JC, Storm C, Bercker S, Pschowski R, Oppert M, Krüger A, et al. Inferior vena cava diameter correlates with invasive hemodynamic measures in mechanically ventilated intensive care unit patients with sepsis. J Emerg Med. 2010;38(5):632-7.
DOI: 10.1016/j.jemermed.2007.11.027
PMID: 18385005
22. Lyon M, Blaivas M, Brannam L. Sonographic measurement of the inferior vena cava as a marker of blood loss. Am J Emerg Med. 2005;23(1):45-50.
DOI: 10.1016/j.ajem.2004.01.004
PMID: 15672337
23. Ciozda W, Kedan I, Kehl DW, Zimmer R, Khandwalla R, Kimchi A. The efficacy of sonographic measurement of inferior vena cava diameter as an estimate of central venous pressure. Cardiovasc Ultrasound. 2016;14(1):33.
DOI: 10.1186/s12947-016-0076-1
PMID: 27542597
24. Ommen SR, Nishimura RA, Hurrell DG, Klarich KW. Assessment of right atrial pressure with 2-dimensional and Doppler echocardiography: a simultaneous catheterization and echocardiographic study. Mayo Clin Proc. 2000;75(1):24-9.
DOI: 10.4065/75.1.24
PMID: 10630753
25. Vaish H, Kumar V, Anand R, Chhapola V, Kanwal SK. The Correlation Between Inferior Vena Cava Diameter Measured by Ultrasonography and Central Venous Pressure. Indian J Pediatr. 2017;84(10):757-62.
DOI: 10.1007/s12098-017-2433-y
PMID: 28868586
26. Hruda J, Rothuis EG, van Elburg RM, Sobotka-Plojhar MA, Fetter WP. Echocardiographic assessment of preload conditions does not help at the neonatal intensive care unit. Am J Perinatol. 2003;20(6):297-303.
DOI: 10.1055/s-2003-42771
PMID: 14528399
27. Natori H, Tamaki S, Kira S. Ultrasonographic evaluation of ventilatory effect on inferior vena caval configuration. Am Rev Respir Dis. 1979;120(2):421-7.
PMID: 475160
28. Gullace G, Savoia MT. Echocardiographic assessment of the inferior vena cava wall motion for studies of right heart dynamics and function. Clin Cardiol. 1984;7(7):393-404.
DOI: 10.1002/clc.4960070704
PMID: 6744695
29. Moreno FL, Hagan AD, Holmen JR, Pryor TA, Strickland RD, Castle CH. Evaluation of size and dynamics of the inferior vena cava as an index of right-sided cardiac function. Am J Cardiol. 1984;53(4):579-85.
DOI: 10.1016/0002-9149(84)90034-1
PMID: 6695787
30. Goei R, Ronnen HR, Kessels AH, Kragten JA. Right heart failure: diagnosis via ultrasonography of the inferior vena cava and hepatic veins. Rofo. 1997;166(1):36-9.
DOI: 10.1055/s-2007-1015374
PMID: 9072102
31. Nagueh SF, Kopelen HA, Zoghbi WA. Relation of mean right atrial pressure to echocardiographic and Doppler parameters of right atrial and right ventricular function. Circulation. 1996;93(6):1160-9.
DOI: 10.1161/01.CIR.93.6.1160
PMID: 8653837
32. Babaie S, Behzad A, Mohammadpour M, Reisi M. A Comparison between the Bedside Sonographic Measurements of the Inferior Vena Cava Indices and the Central Venous Pressure While Assessing the Decreased Intravascular Volume in Children. Adv Biomed Res. 2018;7(1):97.
DOI: 10.4103/abr.abr_213_17
PMID: 30050885
Published
Issue
Section
License
Copyright (c) 2024 Slovenian Medical Journal
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
The Author transfers to the Publisher (Slovenian Medical Association) all economic copyrights following form Article 22 of the Slovene Copyright and Related Rights Act (ZASP), including the right of reproduction, the right of distribution, the rental right, the right of public performance, the right of public transmission, the right of public communication by means of phonograms and videograms, the right of public presentation, the right of broadcasting, the right of rebroadcasting, the right of secondary broadcasting, the right of communication to the public, the right of transformation, the right of audiovisual adaptation and all other rights of the author according to ZASP.
The aforementioned rights are transferred non-exclusively, for an unlimited number of editions, for the term of the statutory
The Author can make use of his work himself or transfer subjective rights to others only after 3 months from date of first publishing in the journal Zdravniški vestnik/Slovenian Medical Journal.
The Publisher (Slovenian Medical Association) has the right to transfer the rights of acquired parties without explicit consent of the Author.
The Author consents that the Article be published under the Creative Commons BY-NC 4.0 (attribution-non-commercial) or comparable licence.